Fetal Patient Monitor

Home » Products » Patient Monitor » Fetal Patient Monitor

Search For

 


Products

Autonomic Neuropathy Analysis System

Ankle Brachial Index Measuring System

Digital Biothesiometer

Spirometer

Cardiovascular Analysis System

Vibratory Perception Threshold Analysis System

Patient Monitor

12 Channel ECG Machine

Fetal Patient Monitor

Model : LPM-905
ECG, Spo2, NIBP, RESP, HR, PR, TEMP, FHR, Toco and FM marker.












Features & Specification

  • Large 12.1” Colour TFT display.
  • Screen Size : 215mm X 160mm.
  • Dimension : 320mm X 240mm X 160mm.
  • Adult to Neonatal Usage.
  • Built-in Thermal Printer.
  • Battery Backup.
  • User Programmable Alarm setting.
  • 24 hour trend information.

ECG
  • Lead : 5 leads (R,L,F,N,C)
  • Lead Selection : 1 ; II ; III ; avR ; avL ; avF ; V; MCL 1.
  • Wave Speed (mm/s) : 12.5/ 25 /50.
  • Sensibility : >200 uV (Peak to peak value).
  • Input Impedance : > 5 megohm.
  • Heart Rate Range : 0-350 bpm
  • Alarm Range : 0-250 bpm
  • Accuracy : 2% or 2 bpm which ever is greater.
  • Resolution : 1 bpm.
  • Wave Form : 7 Channels.
  • Gain Selection : X 0.5 ; X 1 ; X 2 ; X 4.
  • Work Status : OPE, MON, DIA.
  • Lead Fault Alarm : Audible / Visible.
  • Scale Signal : 1mV (Peak to peak value)
  • Veracity : 3%
  • ST Segment Check :
    • Measurement Range : -1.0 mV ~ +1.0 mV
    • Alarm Range : -0.80 mV ~ 0.80 mV
  • ECG Signal Range : 10 (mv) peak to peak value.

Respiration
  • Respiration Method : IRSP.
  • Respiration Rate :
  • Measurement range : 1 - 99 rpm.
  • Alarm Range : 1 - 99 rpm.
  • Accuracy : 2 rpm / 10% which ever is greater.
  • Respiration Scale : X0.5 , X1, X 2, X4.

SpO2
  • Measurement Range : 0- 100 %.
  • Alarm Range : 0-100 %.
  • Resolution : 1%.
  • Accuracy : 80 - 100 %, 2 % 60 - 79 %, 3 %< 60 %, ignored.

Temperature
  • Measurement Range : 0 - 50oC.
  • Alarm Range : 0 - 45oC.
  • Resolution : 0.1oC.
  • Accuracy : 0.2oC.

NIBP
  • Measure Modal :Auto Surge.
  • Working Mode : Auto / Manual.
  • Cycle Time : 1 - 60 min.
  • P R Range : 0 - 300 bpm
  • Overload Protection : Adult / pediatric / neonatal.

Fetal Heart Rate
TOCO/UC
Fetal Movement Marker

Thermal Printer (In-Built)
Built In.
Paper Type : 50mm Roll type.

Power Requirement
  • AC Input : 220 V 10% 50Hz.
  • Internal Battery : 4 A / Hr 12V lead - Acid rechargeable.
  • Battery operation time : 120 min.
  • Charge Time : 6 Hours.

" Due to up-gradation of product,Specification and design are subject to change without prior notice "


* fields are mandatory

INQUIRY FORM

  Contact Information
Contact Person *  
Company Name  
Address *  
Country *  
Email ID *  
Phone Number *  
Fax  
  Inquiry Details
Inquiry For *  
Details *  
Verification Code *     Reload Image
   

  Choose your language :   English  France  Espanol  Italiano  Deutsch  Portugues 

Home   |   Company Profile   |   Products   |   Why Us ?   |   Payment Mode   |   Warehousing   |   Mission & Vision   |   Our Team   |   Contact Us   |   Inquiry   |   Sitemap

Copyright 2009 - 2010. All Rights Reserved. LIFELINE MEDITECH